262 changes: 262 additions & 0 deletions zhaquirks/tuya/ts0601_pool_sensor.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,262 @@
"""Tuya pool sensor."""

import asyncio

from zigpy.quirks.v2 import CustomDeviceV2
from zigpy.quirks.v2.homeassistant import UnitOfElectricPotential, UnitOfTime
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass
from zigpy.quirks.v2.homeassistant.sensor import SensorDeviceClass, SensorStateClass
import zigpy.types as t

from zhaquirks.tuya import TUYA_QUERY_DATA, EnchantedDevice, TuyaNewManufCluster
from zhaquirks.tuya.builder import TuyaQuirkBuilder
from zhaquirks.tuya.mcu import TuyaMCUCluster, TuyaPowerConfigurationCluster

# Create a quirks v2 of Tuya's EnchantedDevice as we need Tuya spells
EnchantedDevice.__bases__ = (CustomDeviceV2,)


class EnchantedDeviceV2(EnchantedDevice):
"""Updated version of EnchantedDevice based on CustomDeviceV2."""

tuya_spell_data_query: bool = True # Enable data query spell
Copy link
Collaborator

@TheJulianJES TheJulianJES Jan 4, 2025

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This can be done properly when #3661 is implemented. (Although I'd like to avoid duplicating the spell code in that PR if that's possible in a clean way.)
I think this implementation might cause the other tests to break at the moment(?)

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I changed the implementation so it doesn't conflict with the tests.



class TuyaPoolManufCluster(TuyaMCUCluster):
def __init__(self, *args, **kwargs):
"""Init."""
super().__init__(*args, **kwargs)
self._update_timer_handle = None
self.check_interval = 60
self.next_refresh_interval = 0
self._loop = asyncio.get_running_loop()
self.handle_auto_update_check_change()

def handle_auto_update_cancel(self):
if self._update_timer_handle:
self._update_timer_handle.cancel()
self._update_timer_handle = None

def handle_auto_update_setup_next_call(self, force_new_interval=False):
tuya_cluster = self.endpoint.device.endpoints[1].in_clusters.get(
TuyaMCUCluster.cluster_id, None
)
if tuya_cluster and "auto_refresh_interval" in tuya_cluster.attributes_by_name:
interval = tuya_cluster.get("auto_refresh_interval", 0) * 60
# Check for a change to auto refresh number
if interval != self.next_refresh_interval:
self.handle_auto_update_cancel()
self.next_refresh_interval = interval
force_new_interval = True

if force_new_interval == True and self.next_refresh_interval > 0:
self.debug(
"using refresh interval of %d minutes", self.next_refresh_interval
)
self._update_timer_handle = self._loop.call_later(
self.next_refresh_interval, self.handle_auto_update_timer_wrapper
)

def handle_auto_update_check_change(self):
self.handle_auto_update_setup_next_call()
self._loop.call_later(self.check_interval, self.handle_auto_update_check_change)

def handle_auto_update_timer_wrapper(self):
self.create_catching_task(self.handle_auto_update())
self.handle_auto_update_setup_next_call(force_new_interval=True)

async def handle_auto_update(self):
tuya_cluster = self.endpoint.device.endpoints[1].in_clusters[
TuyaMCUCluster.cluster_id
]
self.debug("sending refresh query command")
await tuya_cluster.command(TUYA_QUERY_DATA)


(
TuyaQuirkBuilder("_TZE200_v1jqz5cy", "TS0601")
.device_class(EnchantedDeviceV2)
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Use .tuya_enchantment() instead.

.replaces(TuyaPoolManufCluster)
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Use .add_to_registry(replacement_cluster=TuyaPoolManufCluster)

.tuya_battery(dp_id=7, power_cfg=TuyaPowerConfigurationCluster, scale=1)
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

We can use the newer style here, .tuya_battery(dp_id=7, battery_type=BatterySize.Other, battery_qty=1, battery_voltage=30, scale=1) Or whatever the real values are.

.tuya_temperature(dp_id=2, scale=10)
.tuya_sensor(
dp_id=10,
attribute_name="ph_measured_value",
divisor=100,
type=t.uint16_t,
state_class=SensorStateClass.MEASUREMENT,
device_class=SensorDeviceClass.PH,
translation_key="ph_measured_value",
fallback_name="pH",
)
.tuya_sensor(
dp_id=1,
attribute_name="total_dissolved_solids",
type=t.uint16_t,
state_class=SensorStateClass.MEASUREMENT,
translation_key="total_dissolved_solids",
fallback_name="Total Dissolved Solids",
)
.tuya_sensor(
dp_id=11,
attribute_name="ec_measured_value",
type=t.uint16_t,
state_class=SensorStateClass.MEASUREMENT,
translation_key="ec_measured_value",
fallback_name="Electrical Conductivity",
)
.tuya_sensor(
dp_id=117,
attribute_name="salt_measured_value",
type=t.uint16_t,
state_class=SensorStateClass.MEASUREMENT,
translation_key="salt_measured_value",
fallback_name="Salt Concentration",
)
.tuya_sensor(
dp_id=101,
attribute_name="redox_potential",
type=t.uint16_t,
unit=UnitOfElectricPotential.MILLIVOLT,
state_class=SensorStateClass.MEASUREMENT,
translation_key="redox_potential",
fallback_name="ORP Level",
)
.tuya_sensor(
dp_id=102,
attribute_name="cl_measured_value",
type=t.uint16_t,
state_class=SensorStateClass.MEASUREMENT,
translation_key="cl_measured_value",
fallback_name="Chlorine Concentration",
)
# TODO: 103 enum ? pH Calibration
# TODO: 104 bool ?
# TODO: 105 uint16
.tuya_number(
dp_id=106,
attribute_name="ph_max_value",
type=t.uint16_t,
multiplier=0.1,
step=0.1,
min_value=0,
max_value=14,
mode="box",
device_class=NumberDeviceClass.PH,
translation_key="ph_max_value",
fallback_name="pH Maximum Value",
)
.tuya_number(
dp_id=107,
attribute_name="ph_min_value",
type=t.uint16_t,
multiplier=0.1,
step=0.1,
min_value=0,
max_value=14,
mode="box",
device_class=NumberDeviceClass.PH,
translation_key="ph_min_value",
fallback_name="pH Minimum Value",
)
.tuya_number(
dp_id=108,
attribute_name="ec_max_value",
type=t.uint16_t,
multiplier=11,
step=1,
min_value=0,
max_value=20000,
mode="box",
translation_key="ec_max_value",
fallback_name="EC Maximum Value",
)
.tuya_number(
dp_id=109,
attribute_name="ec_min_value",
type=t.uint16_t,
multiplier=1,
step=1,
min_value=0,
max_value=20000,
mode="box",
translation_key="ec_min_value",
fallback_name="EC Minimum Value",
)
.tuya_number(
dp_id=110,
attribute_name="orp_max_value",
type=t.uint16_t,
multiplier=1,
step=1,
min_value=-999,
max_value=999,
mode="box",
unit=UnitOfElectricPotential.MILLIVOLT,
device_class=NumberDeviceClass.VOLTAGE,
translation_key="orp_max_value",
fallback_name="ORP Maximum Value",
)
.tuya_number(
dp_id=111,
attribute_name="orp_min_value",
type=t.uint16_t,
multiplier=1,
step=1,
min_value=-999,
max_value=999,
mode="box",
unit=UnitOfElectricPotential.MILLIVOLT,
device_class=NumberDeviceClass.VOLTAGE,
translation_key="orp_min_value",
fallback_name="ORP Minimum Value",
)
.tuya_number(
dp_id=112,
attribute_name="cl_max_value",
type=t.uint16_t,
multiplier=0.1,
step=0.1,
min_value=0,
max_value=4,
mode="box",
translation_key="cl_max_value",
fallback_name="Cl Maximum Value",
)
.tuya_number(
dp_id=113,
attribute_name="cl_min_value",
type=t.uint16_t,
multiplier=0.1,
step=0.1,
min_value=0,
max_value=4,
mode="box",
translation_key="cl_min_value",
fallback_name="Cl Minimum Value",
)
# TODO: 114 uint16_t payload=0 pH Calibration
# TODO: 115 uint16_t payload=0 EC Calibration
# TODO: 116 uint16_t payload=0 ORP Calibration
# TODO: 118 bool payload=0 (false)
# Press button to manually refresh sensor data.
.command_button(
command_name="query_data",
cluster_id=TuyaNewManufCluster.cluster_id,
translation_key="Update",
fallback_name="Update",
)
# Automatic refresh interval in minutes. Set to 0 to disable.
.tuya_number(
dp_id=0x09,
attribute_name="auto_refresh_interval",
type=t.uint16_t,
translation_key="auto_refresh_interval",
fallback_name="Refresh Interval",
unit=UnitOfTime.MINUTES,
step=5,
min_value=0,
max_value=1440,
)
.add_to_registry()
)
Loading