Skip to content

Commit

Permalink
fixing issues in connect to bus logic
Browse files Browse the repository at this point in the history
  • Loading branch information
joda9 committed Sep 18, 2024
1 parent a8360f4 commit 0b4989f
Showing 1 changed file with 17 additions and 12 deletions.
29 changes: 17 additions & 12 deletions edisgo/network/topology.py
Original file line number Diff line number Diff line change
Expand Up @@ -1910,12 +1910,16 @@ def connect_to_mv(self, edisgo_object, comp_data, comp_type="generator"):
# add component to newly created bus
comp_data.pop("geom")
if comp_type == "generator":
comp_data.pop("type", None)
comp_name = self.add_generator(bus=bus, **comp_data)
elif comp_type == "charging_point":
comp_data.pop("type", None)
comp_name = self.add_load(bus=bus, type="charging_point", **comp_data)
elif comp_type == "heat_pump":
comp_data.pop("type", None)
comp_name = self.add_load(bus=bus, type="heat_pump", **comp_data)
else:
comp_data.pop("type", None)
comp_name = self.add_storage_unit(bus=bus, **comp_data)

# ===== voltage level 4: component is connected to MV station =====
Expand Down Expand Up @@ -2344,7 +2348,7 @@ def connect_to_lv_based_on_geolocation(
edisgo_object,
comp_data: dict,
comp_type: str,
max_distance_from_target_bus: float = 0.1,
max_distance_from_target_bus: float = 0.02,
allowed_number_of_comp_per_bus: int = 2,
allow_mv_connection: bool = False,
factor_mv_connection: float = 3.0,
Expand Down Expand Up @@ -2499,10 +2503,11 @@ def handle_voltage_level_6():
else:
mvlv_subst_id = self.buses_df.loc[target_bus].loc["lv_grid_id"]
comp_data["mvlv_subst_id"] = mvlv_subst_id
comp_name = self.connect_to_lv(edisgo_object, comp_data, comp_type)
comp_name = add_func(bus=target_bus, **comp_data)
return None, comp_name
else:
bus = target_bus
comp_name = self.connect_to_mv(edisgo_object, comp_data, comp_type)
return None, comp_name
return bus, None

def handle_voltage_level_7():
Expand All @@ -2524,9 +2529,7 @@ def handle_voltage_level_7():
]
elif comp_data["sector"] == "work":
lv_loads = self.loads_df[
self.loads_df.sector.isin(
["industrial", "cts", "agricultural", "work"]
)
self.loads_df.sector.isin(["industrial", "cts", "agricultural"])
]
lv_loads = lv_loads.loc[
~lv_loads.bus.isin(self.mv_grid.buses_df.index)
Expand Down Expand Up @@ -2557,17 +2560,17 @@ def handle_voltage_level_7():
mv_buses.distance == mv_buses.distance.min()
]
target_bus = mv_buses_masked.loc[mv_buses_masked.distance.idxmin()]
return target_bus.name
comp_name = self.connect_to_mv(edisgo_object, comp_data, comp_type)
return None, comp_name
else:
# if distance is larger than allowed, create new bus and connect to
# the closest bus via a new line

target_bus = self._connect_to_lv_bus(
edisgo_object, lv_buses.distance.idxmin(), comp_type, comp_data
)
lv_buses_masked = pd.DataFrame(self.buses_df.loc[target_bus]).T
lv_buses_masked["distance"] = 0
mv_buses_masked = pd.DataFrame()
return target_bus
return target_bus, None

# if LV bus is within distance, where no new bus needs to be created, check
# the number of already connected buses, so to not connect too many of the
Expand Down Expand Up @@ -2607,7 +2610,7 @@ def handle_voltage_level_7():
target_bus = lv_buses_masked.loc[lv_buses_masked.distance.idxmin()]
if isinstance(target_bus, pd.DataFrame):
target_bus = target_bus.iloc[0]
return target_bus.name
return target_bus.name, None

# Ensure 'p' is in comp_data, defaulting to 'p_set' or 'p_nom'
if "p" not in comp_data.keys():
Expand Down Expand Up @@ -2637,7 +2640,9 @@ def handle_voltage_level_7():
if comp_name is not None:
return comp_name
elif voltage_level == 7:
bus = handle_voltage_level_7()
bus, comp_name = handle_voltage_level_7()
if comp_name is not None:
return comp_name

# Remove unnecessary keys from comp_data
comp_data.pop("geom", None)
Expand Down

0 comments on commit 0b4989f