Enable PEL for dbus_utility file #562
base: 1110
Are you sure you want to change the base?
Conversation
107c1f7
to
44b7ffd
Compare
@@ -362,11 +363,12 @@ inline types::BiosAttributeCurrentValue | |||
} | |||
catch (const sdbusplus::exception::SdBusError& l_ex) | |||
{ | |||
logging::logMessage( | |||
EventLogger::createSyncPel( | |||
types::ErrorType::InvalidVpdMessage, |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Why invalid vpd message? You car logging it while catching DBus error.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Done
44b7ffd
to
ca72926
Compare
This commit adds code to log a PEL in dbus_utility file, in case of exceptions occurred while doing DBus calls. output: ''' root@p10bmc:~# peltool -i 0x5000000e { "Private Header": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc vpd", "Created at": "01/16/2025 04:47:34", "Committed at": "01/16/2025 04:47:34", "Creator Subsystem": "BMC", "CSSVER": "", "Platform Log Id": "0x5000000E", "Entry Id": "0x5000000E", "BMC Event Log Id": "14" }, "User Header": { "Section Version": "1", "Sub-section type": "0", "Log Committed by": "bmc error logging", "Subsystem": "CEC Hardware - VPD Interface", "Event Scope": "Entire Platform", "Event Severity": "Informational Event", "Event Type": "Miscellaneous, Informational Only", "Action Flags": [ "Event not customer viewable", "Report Externally" ], "Host Transmission": "Not Sent", "HMC Transmission": "Not Sent" }, "Primary SRC": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc vpd", "SRC Version": "0x02", "SRC Format": "0x55", "Virtual Progress SRC": "False", "I5/OS Service Event Bit": "False", "Hypervisor Dump Initiated":"False", "Backplane CCIN": "2E2D", "Terminate FW Error": "False", "Deconfigured": "False", "Guarded": "False", "Error Details": { "Message": "A Dbus internal error occurred." }, "Valid Word Count": "0x09", "Reference Code": "BD554005", "Hex Word 2": "00000055", "Hex Word 3": "2E2D0010", "Hex Word 4": "00000000", "Hex Word 5": "00000000", "Hex Word 6": "00000000", "Hex Word 7": "00000000", "Hex Word 8": "00000000", "Hex Word 9": "00000000", "Callout Section": { "Callout Count": "1", "Callouts": [{ "FRU Type": "Maintenance Procedure Required", "Priority": "Mandatory, replace all with this type as a unit", "Procedure": "BMC0001" }] } }, "Extended User Header": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc error logging", "Reporting Machine Type": "9105-22A", "Reporting Serial Number": "139EF60", "FW Released Ver": "RB1110_025", "FW SubSys Version": "fw1110.00-3.53", "Common Ref Time": "00/00/0000 00:00:00", "Symptom Id Len": "20", "Symptom Id": "BD554005_2E2D0010" }, "Failing MTMS": { "Section Version": "1", "Sub-section type": "0", "Created by": "bmc error logging", "Machine Type Model": "9105-22A", "Serial Number": "139EF60" }, "User Data 0": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc error logging", "BMCLoad": "0.80 0.95 0.87", "BMCState": "Ready", "BMCUptime": "0y 0d 0h 51m 27s", "BootState": "Unspecified", "ChassisState": "Off", "FW Version ID": "fw1110.00-3.53-1110.2503.20250109a (RB1110_025)", "HostState": "Off", "System IM": "50001001" }, "User Data 1": { "Section Version": "1", "Sub-section type": "1", "Created by": "bmc error logging", "DESCRIPTION": "Failed to get object subTree, error: Test Error: org.freedesktop.DBus.Error.AccessDenied: Operation not permitted", "FileName": "/usr/src/debug/openpower-fru-vpd/1.0+git/vpd-manager/include/utility/dbus_utility.hpp", "FunctionName": "getObjectSubTree", "InteranlRc": "0", "UserData1": "", "UserData2": "" } } ''' Signed-off-by: RekhaAparna01 <[email protected]>
ca72926
to
6db36b5
Compare
types::ErrorType::DbusFailure, types::SeverityType::Informational, | ||
__FILE__, __FUNCTION__, 0, | ||
"Failed to get property map, error: " + std::string(l_ex.what()), | ||
std::nullopt, std::nullopt, std::nullopt, std::nullopt); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Not related to this PR, but I think we should have default std::optional<> = std::nullopt
arguments for EventLogger::createSyncPel()
, EventLogger::createAsyncPel()
APIs, otherwise we have to pass std::nullopt
in lot of calls.
This commit adds code to log a PEL in dbus_utility file, in case of exceptions occurred while doing DBus calls.
output: