Expand Up @@ -8,6 +8,20 @@ All dates in this document are approximate.

## Changes

20241203: The resonance test has been changed to include slow sweeping
moves. This change requires that testing point(s) have some clearance
in X/Y plane (+/- 30 mm from the test point should suffice when using
the default settings). The new test should generally produce more
accurate and reliable test results. However, if required, the previous
test behavior can be restored by adding options `sweeping_period: 0` and
`accel_per_hz: 75` to the `[resonance_tester]` config section.

20241201: In some cases Klipper may have ignored leading characters or
spaces in a traditional G-Code command. For example, "99M123" may have
been interpreted as "M123" and "M 321" may have been interpreted as
"M321". Klipper will now report these cases with an "Unknown command"
warning.

20241112: Option `CHIPS=<chip_name>` in `TEST_RESONANCES` and
`SHAPER_CALIBRATE` requires specifying the full name(s) of the accel
chip(s). For example, `adxl345 rpi` instead of short name - `rpi`.
Expand Down
51 changes: 44 additions & 7 deletions docs/Config_Reference.md
Original file line number Diff line number Diff line change
Expand Up @@ -1790,11 +1790,14 @@ section of the measuring resonances guide for more information on
# auto-calibration (with 'SHAPER_CALIBRATE' command). By default no
# maximum smoothing is specified. Refer to Measuring_Resonances guide
# for more details on using this feature.
#move_speed: 50
# The speed (in mm/s) to move the toolhead to and between test points
# during the calibration. The default is 50.
#min_freq: 5
# Minimum frequency to test for resonances. The default is 5 Hz.
#max_freq: 133.33
# Maximum frequency to test for resonances. The default is 133.33 Hz.
#accel_per_hz: 75
#accel_per_hz: 60
# This parameter is used to determine which acceleration to use to
# test a specific frequency: accel = accel_per_hz * freq. Higher the
# value, the higher is the energy of the oscillations. Can be set to
Expand All @@ -1808,6 +1811,13 @@ section of the measuring resonances guide for more information on
# hz_per_sec. Small values make the test slow, and the large values
# will decrease the precision of the test. The default value is 1.0
# (Hz/sec == sec^-2).
#sweeping_accel: 400
# An acceleration of slow sweeping moves. The default is 400 mm/sec^2.
#sweeping_period: 1.2
# A period of slow sweeping moves. Setting this parameter to 0
# disables slow sweeping moves. Avoid setting it to a too small
# non-zero value in order to not poison the measurements.
# The default is 1.2 sec which is a good all-round choice.
```

## Config file helpers
Expand Down Expand Up @@ -4139,15 +4149,16 @@ Support for a display attached to the micro-controller.
[display]
lcd_type:
# The type of LCD chip in use. This may be "hd44780", "hd44780_spi",
# "st7920", "emulated_st7920", "uc1701", "ssd1306", or "sh1106".
# "aip31068_spi", "st7920", "emulated_st7920", "uc1701", "ssd1306", or
# "sh1106".
# See the display sections below for information on each type and
# additional parameters they provide. This parameter must be
# provided.
#display_group:
# The name of the display_data group to show on the display. This
# controls the content of the screen (see the "display_data" section
# for more information). The default is _default_20x4 for hd44780
# displays and _default_16x4 for other displays.
# for more information). The default is _default_20x4 for hd44780 or
# aip31068_spi displays and _default_16x4 for other displays.
#menu_timeout:
# Timeout for menu. Being inactive this amount of seconds will
# trigger menu exit or return to root menu when having autorun
Expand Down Expand Up @@ -4273,6 +4284,31 @@ spi_software_miso_pin:
...
```

#### aip31068_spi display

Information on configuring an aip31068_spi display - a very similar to hd44780_spi
a 20x04 (20 symbols by 4 lines) display with slightly different internal
protocol.

```
[display]
lcd_type: aip31068_spi
latch_pin:
spi_software_sclk_pin:
spi_software_mosi_pin:
spi_software_miso_pin:
# The pins connected to the shift register controlling the display.
# The spi_software_miso_pin needs to be set to an unused pin of the
# printer mainboard as the shift register does not have a MISO pin,
# but the software spi implementation requires this pin to be
# configured.
#line_length:
# Set the number of characters per line for an hd44780 type lcd.
# Possible values are 20 (default) and 16. The number of lines is
# fixed to 4.
...
```

#### st7920 display

Information on configuring st7920 displays (which is used in
Expand Down Expand Up @@ -5004,16 +5040,17 @@ serial:
### [angle]

Magnetic hall angle sensor support for reading stepper motor angle
shaft measurements using a1333, as5047d, or tle5012b SPI chips. The
measurements are available via the [API Server](API_Server.md) and
shaft measurements using a1333, as5047d, mt6816, mt6826s,
or tle5012b SPI chips.
The measurements are available via the [API Server](API_Server.md) and
[motion analysis tool](Debugging.md#motion-analysis-and-data-logging).
See the [G-Code reference](G-Codes.md#angle) for available commands.

```
[angle my_angle_sensor]
sensor_type:
# The type of the magnetic hall sensor chip. Available choices are
# "a1333", "as5047d", and "tle5012b". This parameter must be
# "a1333", "as5047d", "mt6816", "mt6826s", and "tle5012b". This parameter must be
# specified.
#sample_period: 0.000400
# The query period (in seconds) to use during measurements. The
Expand Down
35 changes: 30 additions & 5 deletions docs/G-Codes.md
Original file line number Diff line number Diff line change
Expand Up @@ -127,6 +127,14 @@ use this tool the Python "numpy" package must be installed (see the
[measuring resonance document](Measuring_Resonances.md#software-installation)
for more information).

#### ANGLE_CHIP_CALIBRATE
`ANGLE_CHIP_CALIBRATE CHIP=<chip_name>`: Perform internal sensor calibration,
if implemented (MT6826S/MT6835).

- **MT68XX**: The motor should be disconnected
from any printer carriage before performing calibration.
After calibration, the sensor should be reset by disconnecting the power.

#### ANGLE_DEBUG_READ
`ANGLE_DEBUG_READ CHIP=<config_name> REG=<register>`: Queries sensor
register "register" (e.g. 44 or 0x2C). Can be useful for debugging
Expand Down Expand Up @@ -1059,6 +1067,21 @@ CYCLE_TIME parameter is not stored between SET_PIN commands (any
SET_PIN command without an explicit CYCLE_TIME parameter will use the
`cycle_time` specified in the pwm_cycle_time config section).

### [quad_gantry_level]

The following commands are available when the
[quad_gantry_level config section](Config_Reference.md#quad_gantry_level)
is enabled.

#### QUAD_GANTRY_LEVEL
`QUAD_GANTRY_LEVEL [RETRIES=<value>] [RETRY_TOLERANCE=<value>]
[HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]`: This command
will probe the points specified in the config and then make
independent adjustments to each Z stepper to compensate for tilt. See
the PROBE command for details on the optional probe parameters. The
optional `RETRIES`, `RETRY_TOLERANCE`, and `HORIZONTAL_MOVE_Z` values
override those options specified in the config file.

### [query_adc]

The query_adc module is automatically loaded.
Expand Down Expand Up @@ -1448,11 +1471,13 @@ The following commands are available when the
[z_tilt config section](Config_Reference.md#z_tilt) is enabled.

#### Z_TILT_ADJUST
`Z_TILT_ADJUST [HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]`: This
command will probe the points specified in the config and then make independent
adjustments to each Z stepper to compensate for tilt. See the PROBE command for
details on the optional probe parameters. The optional `HORIZONTAL_MOVE_Z`
value overrides the `horizontal_move_z` option specified in the config file.
`Z_TILT_ADJUST [RETRIES=<value>] [RETRY_TOLERANCE=<value>]
[HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]`: This command
will probe the points specified in the config and then make
independent adjustments to each Z stepper to compensate for tilt. See
the PROBE command for details on the optional probe parameters. The
optional `RETRIES`, `RETRY_TOLERANCE`, and `HORIZONTAL_MOVE_Z` values
override those options specified in the config file.

### [temperature_probe]

Expand Down
18 changes: 18 additions & 0 deletions docs/Measuring_Resonances.md
Original file line number Diff line number Diff line change
Expand Up @@ -694,6 +694,24 @@ If you are doing a shaper re-calibration and the reported smoothing for the
suggested shaper configuration is almost the same as what you got during the
previous calibration, this step can be skipped.

### Unreliable measurements of resonance frequencies

Sometimes the resonance measurements can produce bogus results, leading to
the incorrect suggestions for the input shapers. This can be caused by a
variety of reasons, including running fans on the toolhead, incorrect
position or non-rigid mounting of the accelerometer, or mechanical problems
such as loose belts or binding or bumpy axis. Keep in mind that all fans
should be disabled for resonance testing, especially the noisy ones, and
that the accelerometer should be rigidly mounted on the corresponding
moving part (e.g. on the bed itself for the bed slinger, or on the extruder
of the printer itself and not the carriage, and some people get better
results by mounting the accelerometer on the nozzle itself). As for
mechanical problems, the user should inspect if there is any fault that
can be fixed with a moving axis (e.g. linear guide rails cleaned up and
lubricated and V-slot wheels tension adjusted correctly). If none of that
helps, a user may try the other shapers from the produced list besides the
one recommended by default.

### Testing custom axes

`TEST_RESONANCES` command supports custom axes. While this is not really