Hi, I am not sure if I understand the question. Is the problem that the sensor is still showing error even if the backup jobs finally succeeded? The sensor reports failed jobs within the last 24 h by default. You are not able to reset to green as long a job has failed within the configured time range. |
Ok and are we talking 24h as Midnight to midnight?
Gyslain Hamel
Administrateur de Système/System Administrator
[cid:[email protected]]
[cid:[email protected]]<https://www.canadianbusiness.com/lists-and-rankings/growth-500/2019-information-technology-fastest-growing-companies/>
www.equipemicrofix.com<http://www.equipemicrofix.com/>
Bureau/Office: 514-394-0780
Sans-Frais/Toll-Free: 1-855-305-9939
Fax: 450-933-6229
[mcsa-windows-server-2016-certified-2020]<https://www.youracclaim.com/badges/ac59d77b-9209-48da-bf7a-dfadeaa187c3/public_url>
From: Markus Kraus <[email protected]>
Sent: Wednesday, July 1, 2020 10:16 AM
To: vMarkusK/Advanced-PRTG-Sensors <[email protected]>
Cc: Gyslain Hamel <[email protected]>; Author <[email protected]>
Subject: Re: [vMarkusK/Advanced-PRTG-Sensors] Veeam reports (#58)
Hi,
I am not sure if I understand the question.
Is the problem that the sensor is still showing error even if the backup jobs finally succeeded?
The sensor reports failed jobs within the last 24 h by default. You are not able to reset to green as long a job has failed within the configured time range.
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub<#58 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/AQEOEER5DWCOWDZ3IV2TWNTRZNAJNANCNFSM4ONKNHRA>.
|
The default Timeframe is (Script-execution-Time until (Script-execution-Time -24h) ) |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hi, PRTG keeps showing down for the sensor because the failed backup is at 1
So Simulation
Backup #1 : OK PRTG will show ok
Backup #2 : Failure PRTG will show down because the failure is at 1
Backup #3 : OK PRTG will show down because the failure is at 0
How can i tell PRTG to update the status based on the last report?