Notifications
You must be signed in to change notification settings - Fork 33
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
panic: Both MQTT and Webhook buses are disabled. Nothing to do! #30
Comments
The config snippet that you posted does not format as a valid YAML. I suspect the indentation in your config is not correct, resulting in invalid configuration. If you can, please pot your formatted config or you can use gist to save your config and share the link to it here in the issue. |
I found the error: the check file , config.go checks for both mqtt and webservices. Do we need both?
|
This line checks for when both webhooks and MQTT are disabled. This means there is nothing for this software to do - it needs at least one of those enabled. |
https://gist.github.com/eddiex666/d8a7014ba66e125582def940bf1a3220 I tryed to copy the sample file and remove webhooks and camera. I just need 1 camera and mqtt for the test debug: true hikvision: mqtt: |
i just copy and paste the sample config file into my config.yaml file and i still get the error... |
Maybe someone can send me a valid dummy config file? :-) |
we found the BUG. The config file is not reading from correct path. but in GO file its referating to ./config/config.yaml However the default config file it been generated into the docker container patch, under DIFF, and this file is been read correct. |
Hi guys. I have the same problem. I still don't understand how to fix it? |
Hi, |
2023-02-23T12:38:22.793747923Z panic: Both MQTT and Webhook buses are disabled. Nothing to do!
2023-02-23T12:38:22.793881085Z
2023-02-23T12:38:22.793885081Z goroutine 1 [running]:
2023-02-23T12:38:22.794528495Z github.com/toxuin/alarmserver/config.(*Config).Load(0x8?)
2023-02-23T12:38:22.794644780Z /tmp/app/config/config.go:160 +0xe8b
2023-02-23T12:38:22.794730582Z main.main()
2023-02-23T12:38:22.794974695Z /tmp/app/main.go:25 +0x35
Any ideas?
config file is:
debug: true
hikvision:
enabled: true
cams:
myCam:
address: 192.168.1.19
https: false
username: admin
password: admin
rawTcp: true
mqtt:
enabled: true
username: alarmserver
password: "assword"
port: 1883
server: "192.168.1.20"
topicroot: camera-alerts
testet config file name = config.yml and config.yaml
Running on Ubuntu, Docker
Eddie
The text was updated successfully, but these errors were encountered: