Energy Monitoring

This componet allows you to get additional measurements features with you favorite energy meter. It calculates Apparent Power, Reactive Power and Power Factor.

You can take a look at sample of usage of Energy* components in configuartion for ZMAi-90 energy meter based on TYWE3S: zmai90.yaml

The configuration is very simple. Look at a sample below:

# Example configuration entry
...
external_components:
  - source: github://dentra/esphome-components
...
sensor:
  - platform: "energy_monitoring"
    power: power_id
    voltage: voltage_id
    current: current_id
    apparent_power:
      name: "$name Apparent Power"
    reactive_power:
      name: "$name Reactive Power"
    power_factor:
      name: "$name Power Factor"
    wait_time: 500

Configuration variables:

  • id (Optional, ID): Manually specify the ID used for code generation.
  • power (Required, ID): The ID of the power sensor from your power meter.
  • voltage (Required, ID): The ID of the voltage sensor from your power meter.
  • current (Optional, ID): The ID of the current sensor from your power meter.
  • apparent_power (Optional, Sensor): The sensor with calculated apparent power.
  • reactive_power (Optional, Sensor): The sensor with calculated reactive power.
  • power_factor (Optional, Sensor): The sensor with calculated power factor.
  • wait_time (Optional, int): Time in milliseconds to wait before previous calculations. Defaults to 500ms. Set to 0 to disable it.

Bonus: Works even with pulse meters.

Just set power sensor, but voltage make as static or use it from your smart socket.

Example with static voltage:

# Example configuration entry
sensor:
  - platform: "energy_monitoring"
    power: power_id
    voltage: voltage_id
    apparent_power:
      name: "$name Apparent Power"
    reactive_power:
      name: "$name Reactive Power"
    power_factor:
      name: "$name Power Factor"
      # Supports None or "%" for unit_of_measurement, default: None
      # unit_of_measurement: "%"
  - platform: "template"
    id: voltage
    lambda: return 230.0;

Example with voltage from Home Assistant:

# Example configuration entry
sensor:
  - platform: "energy_monitoring"
    power: power_id
    voltage: voltage_id
    apparent_power:
      name: "$name Apparent Power"
    reactive_power:
      name: "$name Reactive Power"
    power_factor:
      name: "$name Power Factor"
  - platform: "homeassistant"
    id: voltage
    entity_id: "sensor.kitchen_plug_voltage"
    accuracy_decimals: 1